Omron C200HS Garage Door Opener User Manual


 
!
234
If bit 15 of C is ON and more than one address contains the same maximum val-
ue, the position of the lowest of the addresses will be output to D+1.
The number of words within the range (N) is contained in the 3 rightmost digits of
C, which must be BCD between 001 and 999.
When bit 15 of C is OFF, data within the range is treated as normal binary and
when it is ON the data is treated as signed binary.
15 14 13 12 11 00
Data type
1 (ON): Signed binary
0 (OFF): Normal binary
Number of words
in range (N)
Not used – set to zero.
Output address to D+1?
1 (ON): Yes.
0 (OFF): No.
C:
Caution If bit 14 of C is ON, values above #8000 are treated as negative numbers, so the
results will differ depending on the specified data type. Be sure that the correct
data type is specified.
Flags ER: Indirectly addressed DM word is non-existent. (Content of :DM word is
not BCD, or the DM area boundary has been exceeded.)
The number of words specified in C is not BCD (000 to 999).
R
1
and R
1
+N–1 are not in the same data area.
EQ: ON when the maximum value is #0000.
5-21-2 FIND MINIMUM – MIN(––)
R
1
: First word in range
IR, SR, AR, DM, HR, TC, LR
C: Control data
IR, SR, AR, DM, HR, TC, LR
Ladder Symbols Operand Data Areas
@MIN(––)
C
R
1
D
D: Destination word
IR, SR, AR, DM, HR, LR
MIN(––)
C
R
1
D
Limitations N in C must be BCD between 001 to 999.
R
1
and R
1
+N–1 must be in the same data area.
Description When the execution condition is OFF, MIN(––) is not executed. When the execu-
tion condition is ON, MIN(––) searches the range of memory from R
1
to R
1
+N–1
for the address that contains the minimum value and outputs the minimum value
to the destination word (D).
If bit 14 of C is ON, MIN(––) identifies the address of the word containing the
minimum value in D+1. The address is identified differently for the DM area:
1, 2, 3...
1. For an address in the DM area, the word address is written to D+1. For ex-
ample, if the address containing the minimum value is DM 0114, then #0114
is written in D+1.
2. For an address in another data area, the number of addresses from the be-
ginning of the search is written to D+1. For example, if the address contain-
ing the minimum value is IR 114 and the first word in the search range is
IR 014, then #0100 is written in D+1.
Special Math Instructions Section 5-21