Pelco C501M-B (10/97) Home Security System User Manual


 
5-26 Pelco Manual C501M-B (10/97)
5.5.2.4 Programming Receiver Types
Defining the type receiver located at each camera loca-
tion is important to the proper operation of the CM8500
system because the system refers to this table during
other portions of the programming process and also in
the “run” mode. The CM8500 system allows for four
different receiver types: select Cx for a Coaxitron
®
system (including Legacy
®
Coaxitron
®
systems and
Intercept
®
Coaxitron
®
systems without variable speed
or presets), Wx for a Wiretron system, Ic for a Spec-
tra™ or Intercept
®
Coaxitron
®
system with variable
speed or presets, or Is for a Spectra™, Intercept
®
or
Legacy
®
two-wire system. For fixed-mount cameras,
define the receiver input as Cx (see note). To define the
receiver types, refer to Figure 18 and the following pro-
cedure:
NOTE: Some Fixed-mount cameras may have
problems receiving the Coaxitron
®
signal from
the CM8500 system. If this occurs, refer to Sec-
tion 5.5.2.9, Programming User Profiles, and
define those cameras for viewing purposes only.
This will prevent the Coaxitron
®
signal from
being sent to the camera.
1. From the CAM menu, [js to RxType], high-
light and release [point] button.
2. At this time the Receiver Types menu will appear
on the screen. To define a the receiver type for a
specific camera, move the cursor to the desired
column for the camera to be defined and press the
[point] button. Only one column may be selected
at a time.
3. Continue defining receiver types by repeating the
above procedure or press the [CLEAR] key on
the numeric keypad to return to the “run” mode.
Figure 28. Receiver Types Programming Screen
07/09/9309:10:12
Mon: -- Cam: ---
RECEIVER TYPES
Cx Wx Ic Is
1 LOBBY
2 MAIN PARKING
3 MAIN ENTRANCE
4 REAR ENTRANCE
5 LOADING DOCK
6 S E CORNER
7 S W CORNER
8 N E CORNER
*
*
*
*
*
*
*
*