Brother KE-430F Sewing Machine User Manual


 
4. FUNCTION SETTINGS
17
KE-430F, BE-438F
No. Setting range Initial value Setting units Setting details
430F: 1 17
(mm)
472
438F: 1 13
(mm)
1 1
Work clamp/button clamp intermediate drop position setting
* Enabled when No. 470 is set to “OFF”.
<Work clamp lifting height>
* When memory switch No. 470 is set to “ON”, the following parameters are displayed during program mode and sewing
standby mode.
Item
Setting range
and initial value
Display during program mode Display during sewing standby mode
Work
clamp/button
clamp height
(raised)
430F
10 17mm
438F
6 13mm
Setting units: 1mm
(Initial settings are:
430F: 14mm,
438F: 10mm)
Work
clamp/button
clamp height
(intermediate
drop)
430F
1 17mm
438F
1 13mm
Setting units: 1mm
(Initial setting is 1mm)
*
This is displayed
when memory switch
No. 071 is set to “2”
or when memory
switch No. 072 is set
to “2” or “5”.
2780B 2781B
2782B
2783B
For example,
initial value for
430F
Initial value