No. KE-430F-03 KE-430F-05 KE-430F-0K KE-430F-0F BE-438F
151 800 1500 400 800 400
152 1200 2000 800 1200 400
153 2500 2500 1200 2500 600
154 3200 3200 2500 3200 900
155 3200 3200 3200 3200 2700
156 3200 3200 3200 3200 2700
157 3200 3200 3200 3200 2700
158 3200 3200 3200 3200 2700
159 2400 2700 2400 2400 2700
No. Setting range
Initial
value
Setting units Setting details
161 ON/OFF OFF -
Effective hammer operation when needle does not pierce
ON: Enabled
OFF: Disabled
162 ON/OFF OFF -
Regulation of sewing speed changes due to sewing pitch
changes
ON: Restricted (Speed is fixed at the minimum sewing speed
for the maximum pitch of the sewing data.)
* Set to ON if there may be a problem with sewing
speed changes as a result of pitch changes.
OFF: Not restricted (Sewing speed varies depending on
sewing pitch of the sewing data.)
430F: 1200 3200
(sti/min)
3200
163
438F: 1200 2700
(sti/min)
2700
100
Sewing speed limit value
* When setting the sewing speed, the speed will be limited by
this value.
164 ON/OFF OFF -
Thread trimming operation prevention
ON: All thread trimming operations are disabled.
OFF: Thread trimming is carried out in accordance with the
sewing data.
165
-20 20
(degrees)
0 1
Stop position at highest needle position stop
: Becomes higher
+: Becomes lower
166
10 500
(ms)
150 10
Delay time until reverse operation starts during highest needle
position stop operation
167 ON/OFF OFF -
Servo lock operation
ON: Used
OFF: Not used
168
OFF, 1 120
(seconds)
OFF 1
Servo lock timer setting
* Enabled when No. 167 is set to “ON”.
OFF: No timer operation
1 to 120: Timer operation (1 to 120 secs.)
169
30 89
(degrees)
45 1
Servo lock release rotation angle
* Enabled when No. 167 is set to “ON”.
430F: 0 2800
(sti/min)
170
438F: 0 2300
(sti/min)
0 100
Lowers the allowable speed for the sewing pitch by the
amount set.
However, the minimum allowable speed value is 400 sti/min.
171 ON/OFF ON -
Automatic needle lifter operation
ON: If the needle bar is not at the needle up stop position
during work clamp/button clamp home position detection,
it moves automatically to the needle up stop position.
OFF: An “UP” error is displayed without the needle bar moving
automatically.
(No. 655 can also be used to ignore this sensor.)