Brother KE-430F Sewing Machine User Manual


 
4. FUNCTION SETTINGS
16
KE-430F, BE-438F
No. Setting range Initial value Setting units Setting details
407
1 999,
C01 C30
1 -
Program No. assigned to the F1 key
* Enabled when No. 406 is set to “3”.
408
1 999,
C01 C30
2 -
Program No. assigned to the F2 key
* Enabled when No. 406 is set to “3”.
409
1 999,
C01 C30
3 -
Program No. assigned to the F3 key
* Enabled when No. 406 is set to “3”.
410
1 999,
C01 C30
4 -
Program No. assigned to the F4 key
* Enabled when No. 406 is set to “3”.
451 ON/OFF OFF -
Split mode selection
ON: Independent split mode
OFF: Continuous split mode
430F: 40.0
460
0.0 40.0
(mm)
438F: 6.4
0.1 X direction sewing area limitation
430F: 40.0
461
0.0 30.0
(mm)
438F: 6.4
0.1 Y direction sewing area limitation
462
0 8
0 1
Enlargement/reduction reference point
0: Center of sewing frame
1: Sewing start point
2: Center of pattern
3: Front of pattern center
4: Back of pattern center
5: Back-left corner of sewing area
6: Front-left corner of sewing area
7: Back-right corner of sewing area
8: Front-right corner of sewing area
463 ON/OFF OFF -
Enlargement/reduction of bar tacking
ON: Bar tacking stitch lengths (pitch less than approx. 1 mm)
are also enlarged or reduced.
OFF: Bar tacking stitch lengths (pitch less than approx. 1 mm)
are not enlarged or reduced.
465
1 3
1 1
Setting parallel movement amount for sewing pattern
1: The parallel movement amount for the currently-selected
program can be set in parallel movement mode.
The movement amount is initialized when the power is
turned off and when the program number, pattern number,
X-scale or Y-scale is changed.
2: The parallel movement amount for the currently-selected
program can be set in parallel movement mode.
The movement amount is retained when the power is
turned off, but is initialized when the program number,
pattern number, X-scale or Y-scale is changed.
3: The movement amount can be set for each program using
parameters.
The movement amount is retained when the power is
turned off and when the program number, X-scale or
Y-scale is changed, but is initialized when the pattern
number is changed.
469 ON/OFF OFF -
Tension value setting
ON: A common tension value is set for all programs.
* Uniform correction operations are not possible.
OFF: Set separately for each program.
470 ON/OFF OFF -
Work clamp/button clamp height setting for each program
ON: Work clamp/button clamp height is set separately for each
program.
OFF: A common work clamp/button clamp height is set for all
programs.
* The work clamp/button clamp height is set by Nos. 471
and 472.
430F: 10 17
(mm)
14
471
438F: 6 13
(mm)
10
1
Work clamp/button clamp raise position setting
* Enabled when No. 470 is set to “OFF”.