Enter the number of history records you wish to delete, and press [#/Enter]. The previous
menu appears.
Default EE
!
Warning!
Lost programming!
All programming, including zone configurations and option installations, are lost when this op-
eration is performed. You must turn control panel power off and on after resetting the de-
fault, to reinstall the four zone expanders and the MUX expander. You must update the option
bus and set up keypads (PROG SYSTEM MENU) to reinstall option bus devices.
Shortcut: 0-PROG, 8-HSTRY DEFLTS, 2- DEFAULT EE
You can set the control panel back to the original factory-programming configuration with this
option. You are asked to press [#/Enter] to complete the operation. Press [*/Back] to cancel
the operation.
The following window appears:
SETTING EEPROM
TO DEFAULT...
When the operation is complete, the previous menu appears. This operation takes several
minutes when the D7039 Multiplex Expander is installed.
Alternate 4/2 Codes
Shortcut: 0-PROG, 8-HSTRY DEFLTS, 3- ALT 4/2 CDES
You can set all of the programming for 4/2 codes to an alternative set of default reports, as
described in Appendix D, 110. To cause a complete control panel default, use the default EE
option.
The following window appears:
SETTING EEPROM
TO DEFAULT...
When the operation is complete, the previous menu appears.
Program MUX
Shortcut: 0-PROG, 9-PROGRAM MUX
!
Warning!
1. Unprogrammed devices on the bus will not operate or be supervised
2. This menu is accessible only when the D7039 Multiplex expander is installed.
3. Do not install more than one device programmed to the same address on the bus. Doing so
can inhibit alarm reporting from both devices.
i
Notice!
Intermittent trouble reports from a particular MUX point address can indicate that more than
one device was programmed to that address.