Teledyne T360M Carbon Monoxide Alarm User Manual


 
1 2 3 4 5 6
A
B
C
D
654321
D
C
B
A
APPROVALS
DRAWN
CHECKED
APPROVED
DATE
SIZE DRAWING NO. REVISION
SHEET
The information herein is the
property of API and is
submitted in strictest con-
Unauthorized use by anyone
fidence for reference only.
for any other purposes is
prohibited. This document or
any information contained
in it may not be duplicated
without proper authorization.
Schematics for PWB 04087
A
1 1
2-Apr-2002
LAST MOD.
B
of
CAC 4/30/01
04089
1
2
3
4
5
6
J2
R1
357
R4
2K
R2
2K
C1
1.0uF
+5V
TP1
TP2
R3
1 K
R7
151K
R8
150K
R5
150K
R6
150K
+5V
+5V
1
2
3
147
U1A
MC74HC132A
4
5
6
147
U1B
MC74HC132A
9
10
8
147
U1C
MC74HC132A
12
13
11
147
U1D
MC74HC132A
O2
OPB804
O1
OPB804
R10
200
R9
200
C2
1.0uF
C3
1.0uF
and PCA 04088
OPTO-INTERRUPTER
07272B DCN6552
D-13