GE 60-960-95 Home Security System User Manual


 
Concord Ultra
85
Table B3: System Event Trigger Numbers
System Event Description
Trigger
No.
Null Trigger (used for direct control) Activated only by schedule or direct command. 000
Fire Alarm When Fire sirens are started. 001
Police Alarm When Police sirens are started. 002
Auxiliary Alarm When Auxiliary sirens are started. 003
Any Audible Alarm When any of the above sirens are started. 004
Silent Alarm (sensor groups 2, 3, and duress)
When a sensor in group 2 or 3 goes into alarm or when a
duress alarm is activated (does not include groups 25, 27, 28,
or 32).
005
Any Audible or Silent Alarm
When any alarm is started (does not include groups 25, 27, 28,
or 32).
006
HOM Group 27, 28, 32 in Alarm When a sensor in group 27, 28, or 32 goes into alarm. 007
Major Trouble (phone or receiver failure) When a receiver failure (S94) or a phone failure (S96) occurs. 008
Arming to STAY or AWAY When the panel is armed to level 2 or 3. 009
Arming to AWAY When the panel is armed to level 3. 010
AVM is Interactive (audio session in progress)
When the central station operator begins listening or talking to
the premises.
011
Fail-to-Communicate (panel can’t call CS or pager) When the fail-to-communicate output is activated. 012
AVM Trip (edge) When an AVM alarm occurs, output is activated momentarily. 013
Keychain Touchpad Star Button-Press When the star button on a keychain touchpad is pressed. 014
Smoke Power (for resetting 4-wire smoke detectors) Deactivated when hardwire smoke detectors need to be reset. 015
Exterior Siren Activated for police or fire alarms. 016
Interior Siren Activation follows all system noises 017
AVM Trip (pulse) When an AVM alarm occurs, output is deactivated for 10 ms 018
State of System Status Follows the state of system status (ready or trouble). 019
Tamper Condition When any tamper is tripped 020
Closing Report Sent
When a closing report has been successfully transmitted to the
central station.
021
Group XX in Alarm When any sensor in group XX goes into alarm Table B4
Sensor XX in Alarm When sensor number XX goes into alarm Table B4
Sensor XX Open When sensor number XX is opened Table B4
Table B4: Sensor Group Event Trigger Numbers
Sensor Group Trigger No. Sensor Group Trigger No.
Group 00 in alarm 064 Group 17 in alarm 081
Group 01 in alarm 065 Group 18 in alarm 082
Group 02 in alarm 066 Group 19 in alarm 083
Group 03 in alarm 067 Group 20 in alarm 084
Group 04 in alarm 068 Group 21 in alarm 085
Group 05 in alarm 069 Group 22 in alarm 086
Group 06 in alarm 070 Group 23 in alarm 087
Group 07 in alarm 071 Group 24 in alarm 088