GE 60-960-95 Home Security System User Manual


 
Concord Ultra 2
Immediate Beeps set to on
UL 98 Options set to on
Receiver Failure set to on (if wireless devices are used)
Siren Verify set to on
RF TX Timeout set to 4 hours (if system includes a built in or SuperBus 2000 RF Receiver
and wireless smoke sensors)
Sleep Time set to off
Siren Timeout set to 4 minutes or more
Two Trip Error set to off
Disable Trouble Beeps set to off
UL 1023 & 985 24-Hour Backup
For 24-hour backup, the total current draw for all connected devices is limited to 190 mA (during
normal standby conditions) using a 7.0 AH battery.
SIA System Requirements
Note
UL requirements take prior-
ity over SIA requirements.
SIA system requirements are the same as those described for a UL Listed Basic System on page
1, plus:
If multiple annunciation is required, use Hardwire Siren part no.13-046.
SIA Setting Requirements
The following table describes programming requirements to meet ANSI-SIA CP-01.
The following table describes non-programmable (hard coded) system operation as required to
meet ANSI-SIA CP-01 and is provided only for your reference.
Shortcut # Function Programming
Page
Reference
Testing
Page
Reference
Default
Setting
Required Setting
0004 SIA False Alarm
Reduction
25 63 On On
partition 1: 0013
partition 2: 0023
Exit Extension 26 63 On On
partition 1: 0014
partition 2: 0024
Auto Stay Arming 26 63 On On
partition 1: 0017
partition 2: 0027
Duress Code 27 63 Disabled Disabled
02005 Dialer Abort 33 63 On On
02006 Dialer Abort Delay 33 63 30 Sec. 15-45 sec.
02007 Cancel Message 33 63 On On
02009 Call Wait Cancel 34 63 Disabled On if reporting to central station and
customer has call waiting service
partition 1: 0310
partition 2: 0320
Entry Delay 37 63 30 sec. 30-240 sec.
partition 1: 0311
partition 2: 0321
Exit Delay 37 63 60 sec. 45-184 sec.
06014 Swinger Limit 43 63 1 1
1100 Smoke Verify 54 63 Off On if smoke alarms are
programmed into system
N/A Cross Zoning 83 63 Disabled Enabled for zones with a high
probability of false alarms
Function Operation
Disarm During Entry Delay Enter Code Only (or 1 + CODE)