GE 60-960-95 Home Security System User Manual


 
Concord Ultra 76
* These devices not listed, investigated, or verified by UL.
Listed, but not tested for compatibility by UL.
Table A2: Hardwire Devices
Part No. Description Qty.
mA
(Max.)
Sub Total
Hardwire Sensors/Detectors
1035-N Magnetic Contact 3/8” press fit N/A
1075-N Magnetic Contact – surface mount N/A
N/A
System Sensor models 2100D, 2100TD,
2100S, 2100TS, 2400, or 2400TH or ESL
series 429AT, 521B or 521BXT
10 mA
Sirens
60-736* Supervised Wireless Siren N/A
60-483-01 Slim Line Hardwire Interior Siren 120 mA
13-046 Hardwire Exterior Siren 145 mA
SuperBus 2000/Miscellaneous Components
60-746-01 2x16 LCD Alphanumeric Touchpad 90 mA
60-820 Fixed Display LCD Touchpad 30 mA
60-803 2x20 LCD Alphanumeric Touchpad 120 mA
60-804 2x20 VFD Alphanumeric Touchpad 120 mA
60-755* Power Line Carrier Card 110 mA
60-756 4 Input/2 Output SnapCard 185 mA
60-757 8Z Hardwire Zone Expander SnapCard 230 mA
60-758 4 Output SnapCard 130 mA
60-774 Hardwire Input Module 18 mA
60-770 Hardwire Output Module 91 mA
60-620-01 Energy Saver Module 20 mA
60-677* Interrogator 200 Audio Verification Module 10 mA
60-850
Standard*
Cellular Backup Module
1600 mA
60-850-01
High Power*
1900 mA
60-783-02 Automation Module 35 mA
60-861* Wireless Gateway Module 1600mA
Total power consumption: mA
Total power consumption using 50 VA transformer and 7.0 AH backup battery
not to exceed:
1,350 mA
Table A3: Zone and Sensor Assignments
No. RF Zone
Module Bus
ID Number
Module
Input
Number
Group Partition Zone/Sensor Text
01
02
03
04
05
06
07
08