GE 60-960-95 Home Security System User Manual


 
Concord Ultra
45
Siren Options Menu
The SIREN OPTIONS menu lets you set up siren operation and supervision.
The following describes how to program the siren option settings that appear under
GLOBAL.
Freeze Alarm (partition 1: 06107, partition 2: 06207)
Reporting-Partition 1-2 (Default = off)
This setting determines whether the panel reports a freeze alarm to
the central station or pager, when the selected partition’s energy
saver module detects a temperature that matches a predetermined
setting (see
BUS DEVICES—UNIT ID—ENERGY OPTIONS—FREEZE
TEMP
).
¾
To turn Freeze Alarm reporting off or on:
1. With the desired partition selected, press A or B until
the display shows
FREEZE ALARM OFF/ON (current
setting).
2. Press 1 (off) or 2 (on). The display flashes the entered
setting.
3. Press # and the display shows the new setting.
Alarm Verify (partition 1: 06108, partition 2: 06208)
Reporting-Partition 1-2 (Default = off)
This setting determines whether the panel reports to the central
monitoring station after a single sensor or zone trip (off) or waits
for a second trip before reporting (on).
This setting affects sensors/zones in groups 10 through 20. If
Alarm Verify is set to on, group 18 responds the same as group 17
(see “Appendix B, Table B1 “Sensor Group Characteristics”).
Note
For UL Listed installations, Alarm Verify must be set to off.
¾To turn Alarm Verify off or on:
1. With the display showing ALARM VERIFY OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
System Tamper (partition 1: 06109, partition 2: 06209)
Reporting-Partition 1-2 (Default = off)
This setting determines how the panel handles possible tamper situations.
When this feature is on, the panel reacts in the following two ways:
The system goes into alarm if several attempts are made to disarm the
system with incorrect access codes (40 consecutive keypresses).
The panel reports to the central station if a bus device stops communi-
cating with the panel.
¾
To change the System Tamper setting:
1. With the display showing SYSTEM TAMPER
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Immediate Beeps (0700)
Siren Options-Global (Default = off)
This setting determines whether the panel activates trouble beeps as soon
as a wireless device supervisory condition is detected (on), or if the panel
waits until “supervisory time” to activate trouble beeps (off). (Refer to
TIMERSGLOBALSUPERVISORY TIME).
Note
For UL Listed installations, this feature must be on.
¾To turn Immediate Beeps off or on:
1. With the display showing IMMEDIATE BEEPS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Disable Trouble Beeps (0701)
Siren Options-Global (Default = off)
When this setting is on, the panel will not beep to alert users of wireless
device supervisory trouble.
Note
For UL Listed installations, Disable Trouble Beeps must be set to off.
¾To turn Disable Trouble Beeps off or on:
1. With the display showing DISABLE TR BEEPS
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.