Concord Ultra 42
TP Panic RPT FMT (06009)
Reporting-Global (Default = off)
This setting determines how the panel formats touchpad panic alarm
reports to the central station.
When this feature is turned on, touchpad panic alarms report using the
following 3-digit codes:
Auxiliary—597, Police—598, Fire—599
When turned off, touchpad panic alarms report using a 3-digit code from
500 to 515, with the last digit identifying the touchpad device number.
¾
To turn TP Panic RPT FMT off or on:
1. With the display showing TP PANIC RPT FMT
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
AC Failure (06010)
Reporting-Global (Default = off)
When this setting is on, the panel reports to the central station 15 min-
utes after AC power to the panel is lost.
Note
For UL 1635 listed installations, this feature must be set to on.
¾To turn AC Failure reports off or on:
1. With the display showing AC FAILURE OFF/ON
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.
Receiver Failure (06011)
Reporting-Global (Default = off)
When this setting is on, the panel reports a receiver failure under the fol-
lowing conditions:
No wireless sensor signals have been received for two hours or
The receiver is being jammed with a constant signal.
Note
For UL Listed installations using wireless devices, Receiver Failure must be set
to on.
¾To turn Receiver Failure reports off or on:
1. With the display showing RECEIVER FAILURE
OFF/ON
(current setting), press 1 (off) or 2
(on). The display flashes the entered setting.
2. Press # and the display shows the new set-
ting.
RF Low Bat Rpt (06012)
Reporting-Global (Default = weekly)
This setting determines whether the panel sends daily or
weekly low battery reports to the central monitoring station
when a wireless device is reporting a low battery condition
to the panel.
¾
To set RF Low Battery Report to daily or weekly:
1. With the display showing RF LOW BAT RPT DAILY/WEEKLY
(current setting), press 1 (daily) or 2 (weekly). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
RF Supv Rpt (06013)
Reporting-Global (Default = weekly)
This setting determines whether the panel sends daily or
weekly reports to the central monitoring station when the
panel detects a supervisory condition in a wireless device.
¾
To set RF Supv Report to daily or weekly:
1. With the display showing RF SUPV REPORT DAILY/WEEKLY
(current setting), press 1 (daily) or 2 (weekly). The display
flashes the entered setting.
2. Press # and the display shows the new setting.