GE 60-960-95 Home Security System User Manual


 
Concord Ultra
1
About This
Manual
This manual provides information for planning, installing, programming, and testing this security
system. When necessary, this manual refers you to other documentation included with compati-
ble peripherals.
Planning sheets are included for you to record hardware layout and software programming set-
tings.
About the User’s Guide
The User’s Guide (466-2060) contains user worksheets that should be filled out during the instal-
lation and programming of the system. With two partition systems, a User’s Manual for each par-
tition is suggested.
Special Installation Requirements
This security system can be used as a fire warning system, an intrusion alarm system, an emer-
gency notification system, or any combination of the three.
Some installations may require configurations dictated by city/state codes, insurance, or Under-
writer’s Laboratories (UL). This section describes the various component and configuration list-
ings.
UL Listed Installations
This section describes the requirements for UL Listed installations.
Basic System
Control Panel (60-960-95)
Backup Battery 12V 7 AH (60-680)
•SuperBus
®
2000 Fixed Display Touchpad (60-820), 2x16 LCD Touchpad (60-746-01), 2x20
LCD Touchpad (60-803-04), or 2x20 VFD Touchpad (60-804-04)
Class II 24 VAC, 50 VA Line Carrier Power Transformer (60-779)
Interior Speaker Siren (60-252), Exterior Speaker Siren (13-060), Slim Line Hardwire Inte-
rior Siren (60-483-01) or Hardwire Exterior Siren (13-046) per partition
Household Burglary Alarm System Unit (UL 1023)
Basic system, plus:
Hardwire Magnetic Contact (1035-N or 1075-N) or Wireless Learn Mode Door/Window
Sensor (60-362)
Immediate Beeps set to on
UL 98 Options set to on
Receiver Failure set to on (if wireless devices are used)
Siren Verify set to on
Exit Delay set to 60 seconds
Quick Exit set to off
Siren Timeout set to 4 minutes or more
Entry Delay set to 45 seconds or less
RF TX Timeout set to 24 hours (if system includes a built in or SuperBus 2000 RF Receiver
and wireless smoke sensors)
Extended Delay set to off
Sleep Time set to off
Two Trip Error set to off
Alarm Verify set to off
Disable Trouble Beeps set to off
Household Fire Warning System (UL 985)
Basic system, plus:
Hardwire Smoke Detector: System Sensor models 2100D, 2100TD, 2100S, 2100TS, 2400,
or 2400TH learned into sensor group 26 or Sentrol (ESL) models 429AT, 521B or 521BXT
learned into sensor group 26
Wireless Smoke Sensor 60-506-319.5, 60-848-02-95 or 60-848-02-95 learned into sensor
group 26