GE 60-960-95 Home Security System User Manual


 
Concord Ultra 4
Up to 96 wireless or hardwired zones
Standard Panel
The following describe the basic panel (out-of-box) hardware capabilities.
Power: Input for an AC step-down, plug-in style transformer.
Auxiliary Power Output: Output that supplies 8.5 to 13.5 VDC with up 1.35 amps (with
panel powered by 50 VA transformer) for bus devices and hardwired detectors, such as
smoke and motion detectors.
Bus A and B: Input and output that provides communication between bus devices and the
panel.
Siren Driver: Output that can drive an 8-ohm load and provides intrusion and fire alarm
sounds for partition 1.
2 Onboard Outputs: Open-collector outputs that can be set up to activate other signalling
devices, based on system events.
Microphone Input: Input used for 2-way audio when used in conjunction with the Interro-
gator 200 Audio Verification Module.
8 Supervised Hardwire Zones: Inputs for various hardwired detectors. Zone 8 can be set
up in programming to accept 2-wire smoke detectors.
Built-In SuperBus 2000 Transceiver allows use of up to 96 319.5 MHz. crystal Learn
Mode wireless sensors and touchpads. Also allows supervision of supervised wireless sirens.
Built-In Phone Supervision Card allows the panel to check for the correct phone line volt-
age (partition 1 only), upon dialing the central station/pager number. The panel can also be
programmed to check the phone line voltage automatically.
Built-In SuperBus 2000 Phone/Interface Voice Module allows system access and control
using touch-tone telephones, on- or off-site. The module includes an output for a speaker
that sounds system status and alarm voice messages.
Built-In Power Line Carrier Card allows the system to use supervised wireless sirens and
X10
Powerhouse Lamp Modules for light control and light activation during alarms.
Phone Line Connection: Allows panel to communicate with central monitoring station and/
or pagers.
SuperBus 2000 Touchpads
The following describes the different touchpads that can be used for system programming and
operation.
SuperBus 2000 Fixed Display Touchpad: Provides operation control and user-program-
ming access (not installer/dealer programming). Displays system messages and indicates
system status.
SuperBus 2000 2x16 LCD Touchpad: Provides complete system programming and opera-
tion control. Displays system messages that prompt users for information when needed and
indicates system status.
SuperBus 2000 2x20 LCD Touchpad: Provides complete system programming and opera-
tion control. Large display shows system messages that prompt users for information when
needed and indicates system status.
SuperBus 2000 2x20 VFD Touchpad: Provides complete system programming and opera-
tion control. Large fluorescent display shows system messages that prompt users for infor-
mation when needed and indicates system status.
Supervised Wireless Siren
Supervised Wireless Sirens plug into any standard electrical outlet and produce status and alarm
sounds. The panel sends signals to the siren through the Power Line Carrier Card and Line Car-
rier Power Transformer, through the AC electrical wiring.
The siren has a built-in transmitter that is used for supervising with the panel. With the siren
transmitter learned into panel memory (panels with receivers), the siren can notify the panel if it
is unplugged, stops receiving panel signals, or has a low backup battery.
SnapCards
The following SnapCards expand the system as described:
8Z Input SnapCard: Provides eight additional hardwire zone inputs, of which two are ded-
icated for using two wire smoke detectors.