GE 60-960-95 Home Security System User Manual


 
Concord Ultra 34
The following sections describe the phone option settings that appear under PARTITION 1-2.
A Phone Interface/Voice module must be installed for the system to use the settings under
PHONE
OPTIONS— PARTITION 1-2
.
Pager Delay (02008)
Phone Options-Global (Default = 15 sec.)
This setting determines how long a report is delayed to a
pager, after the panel dials the pager number.
Note
The Pager Delay time should not be set below 5 seconds,
unless absolutely necessary.
¾To set the Pager Delay time:
1. With the display showing PAGER DELAY nn SECS (current set-
ting), enter a delay time (0–30). The display flashes the
entered setting.
2. Press # and the display shows the new setting.
Call Wait Cancel (02009)
Phone Options-Global (Default = none)
This feature lets you set up a dialing prefix to disable the call waiting feature
before the panel makes its first dialing attempt to any programmed central
monitoring station or downloader phone number. The prefix can be up to
eight digits.
To enter pauses, press C.
To enter *, press and hold 7 for one second.
To enter #, press and hold 9 for one second.
¾
To set up Call Wait Cancel:
1. With the display showing CALL WAIT CAN-
CEL __
(or current setting), enter the
desired prefix. The display flashes the
entered setting.
2. Press # and the display shows the new set-
ting.
¾
To delete the Call Wait Cancel prefix:
1. With the display showing CALL WAIT CAN-
CEL __ (or current setting), press D.
DO NOT change this option from its default if the customer doesn’t
have call waiting. Verify with the customer that they have call waiting
with their phone service provider before changing this option from its
default. Changing this option from its default without call waiting
will prohibit the panel from calling the central station.
Caution
!
Dial Tone Detect (02010)
Phone Options-Global (Default = on)
When this setting is on, the panel begins dialing as
soon as it detects a dial tone. When this feature is
off, the panel begins dialing a few seconds after
seizing the phone line.
Note
There is no Dial Tone Detect on the last dialing
attempt.
¾To set up Dial Tone Detect:
1. With the display showing DIAL TONE DETECT OFF/ON (current set-
ting), press 1 (off) or 2 (on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Local Phone Control (partition 1: 0210,
partition 2: 0220)
Phone Options-Partition 1-2 (Default = on)
When this feature is on, the panel can be accessed
from a phone on the premises.
¾
To set up Local Phone Control:
1. With the display showing LOCAL PHONE CTRL OFF/ON (current set-
ting), press 1 (off) or 2 (on). The display flashes the entered setting.
2. Press # and the display shows the new setting.
Remote Access (partition 1: 0211, par-
tition 2: 0221)
Phone Options-Partition 1-2 (Default = on)
When this setting is on, the panel can be accessed
from an off-site phone.
¾
To turn Remote Access off or on:
1. With the display showing REMOTE ACCESS OFF/ON (current setting),
press 1 (off) or 2 (on). The display flashes the entered setting.
2. Press # and the display shows the new setting.