GE 60-960-95 Home Security System User Manual


 
Concord Ultra 46
The following sections describe the settings that appear under SIREN OPTIONS—PARTITION 1.
Sensors Menu
The SENSORS menu gives you access to the following settings:
LEARN SENSORS lets you add (learn) hardwire zones, wireless sensors, and wireless touch-
pads into panel memory.
SENSOR TEXT lets you “name” the sensors and zones you have added to the system.
DELETE SENSORS lets you delete zones and sensors from panel memory.
UL 98 Options (0702)
Siren Options-Global (Default = off)
This setting determines whether the panel complies with UL 98 require-
ments (4-hour trouble beep restart, 4-hour backup battery test, 4-hour
smoke (group 26) zone supervisory).
Note
For UL Listed installations, this feature must be on.
¾To turn UL 98 Options off or on:
1. With the display showing UL 98 OPTIONS OFF/
ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
SWS Supv Code (0703)
Siren Options-Global (Default = 3)
This setting determines the system house code number used for supervis-
ing wireless sirens.
Note
To supervise wireless sirens, the siren must be learned into sensor group 33 for
the system to process radio signals from wireless sirens.
Supervised Wireless Sirens receive signals from the panel through the
existing electrical wiring. If sirens fail to receive or process these signals,
the siren transmits a wireless signal to the panel/ receiver.
Note
You must set both the SWS Supv Code and the partition House Code (see the
LIGHT CONTROL menu) before plugging in Supervised Wireless Sirens.
¾To set the SWS Supv Code:
1. With the display showing SWS SUPV CODE nnn
(current code), enter the desired code (1–
255). The display flashes the entered code.
2. Press # and the display shows the new code.
Global Fire (0704)
Siren Options-Global (Default = off)
This setting determines whether or not sirens in both partitions sound (on)
if either partition activates a fire alarm.
¾
To turn Global Fire off or on:
1. With the display showing GLOBAL FIRE OFF/
ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
Siren Verify (0710)
Siren Options-Partition 1 (Default = off)
This setting determines whether or not the panel supervises the panel
speaker terminals (7–8). When this feature is on, the panel will indicate a
trouble condition if no speaker is connected to panel speaker terminals.
Note
For UL Listed installations, Siren Verify must be set to on.
¾To turn Siren Verify off or on:
1. With the display showing SIREN VERIFY OFF/
ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.