GE 60-960-95 Home Security System User Manual


 
Concord Ultra
57
Direct Bypassing
(030nnn1 where nnn=user
number 00-229)
User Codes-Reg. User Codes-User NNN (Default = off)
This setting determines whether or
not a specific user code provides
access to the “bypass sensors” fea-
ture. Set this feature to “on” for all
users who need to be able to
bypass sensors.
¾
To turn user code Direct Bypassing off or on:
1. With the display showing USER CODES, press # and the display shows REGULAR USER
CODES.
2. Press #
and the display shows USER nnn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER
nnn - nnnn.
4. Press A or B until the display shows
DIRECT BYPASSING OFF/ON (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display
shows the new setting.
Remote Access (030nnn2
where nnn=user number
00-229)
User Codes-Reg. User Codes-User NNN (Default = off)
This setting determines whether or
not the user can access the panel
from a remote phone (a phone
located off the premises).
¾
To turn user code Remote Access off or on:
1. With the display showing USER CODES, press # and the display shows REGULAR USER
CODES.
2. Press #
and the display shows USER nn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER
nnn - nnnn.
4. Press B until the display shows
REMOTE ACCESS ON/OFF (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting.
6. Press # and the display shows the new setting.
Partition Jump (030nnn3
where nnn=user number
00-229)
User Codes-Reg. User Codes-User NNN (Default = off)
This setting determines whether or
not a specific user code can access
one or both partitions. When this
is set to on, the user can access
both partitions.
¾
To turn user code Partition Jump off or on:
1. With the display showing USER CODES, press # and the display shows REGULAR USER
CODES.
2. Press #
and the display shows USER nnn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER
nnn - nnnn.
4. Press B until the display shows PARTITION JUMP OFF/ON (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting.
6. Press # and the display shows the new setting.
System Tests (030nnn4
where nnn=user number
00-229)
User Codes-Reg. User Codes-User NNN (Default = off)
This setting determines whether or
not a specific user code provides
access to the phone and sensor
tests. Set this feature to “on” for
all users who need to be able to
conduct phone and sensor tests.
¾
To turn user code System Tests off or on:
1. With the display showing USER CODES, press # and the display shows REGULAR USER
CODES.
2. Press #
and the display shows USER nnn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER
nnn - nnnn.
4. Press A or B until the display shows
SYSTEM TESTS OFF/ON (current setting).
5. Press 1 (off) or 2 (on). The display flashes the entered setting.
6. Press # and the display shows the new setting.