GE 60-960-95 Home Security System User Manual


 
Concord Ultra
21
Powering Up the Panel
After connecting and wiring all devices to the panel, you are ready to apply AC and backup bat-
tery power to the panel. The panel comes with the backup battery leads already connected to the
lugs on the panel.
¾
To power up the panel:
1. Connect the red and black battery leads not already connected to the lugs on the panel to the
battery terminals (see Figure 24).
2. Plug the transformer into an outlet that is not controlled by a switch.
Alphanumeric touchpads display
************, then SCANNING BUS DEVICES, and finally a
date and time display.
Note
If alphanumeric touchpads
don’t display anything,
immediately unplug the
transformer and disconnect
the backup battery. Refer to
the “Troubleshooting” sec-
tion.
3. To permanently mount the transformer, unplug it and remove the existing screw securing the
AC outlet cover.
4. Hold the outlet cover in place and plug the transformer into the lower receptacle.
5. Use the screw supplied with the transformer to secure the transformer to the outlet cover.
Programming
the Panel
For on-site system programming, an alphanumeric touchpad is required.
Entering Program Mode
Entering program mode is done using an installer/dealer code (default = 4321). The system can
be put into program mode only when the system is disarmed.
Note
If the system is powered up
after the programming
touchpad is connected or if a
bus command scan is exe-
cuted, the programming
touchpad will be “learned”
into the system and must
later be manually deleted.
¾To enter program mode:
1. Make sure the system is disarmed in all partitions.
2. Press 8 + 4321 + 0 + 0. The display shows
SYSTEM PROGRAMMING.
¾
To enter programming mode using a programming touchpad:
1. Connect the wires from the Programming Touchpad Cable (60-791) to the power and bus
wires on an alphanumeric touchpad, matching the wire colors on each.
2. Make sure the system is powered up and disarmed.
3. Connect the plug on the cable onto the panel programming touchpad header (see Figure 25).
4. Press 8 + 4321 + 0 + 2. The touchpad sounds one short beep. Press * and verify that the dis-
play shows
SERVICE TOUCHPAD ACTIVE.
5. Press 8 + 4321 + 0 + 0 and the display shows
SYSTEM PROGRAMMING.
6. After programming is completed, simply disconnect the touchpad from the panel header.
Figure 25. Connecting a Programming Touchpad
Use extreme caution when securing the transformer to a metal outlet cover. You could
receive a serious shock if a metal outlet cover drops down onto the prongs of the plug
while you are securing the transformer and cover to the outlet box.
Warning
!
6 0 7 3 4 G 3 0 8 D .D S F
Status
Features
press both
Lights
System
Away
Pager
Off
No Delay
press both
press both
Test System Weekly
Silent
Stay
D
*
7
0 #
8
B
A
4
1
5
6
2
3
Bypass
Menu
C
9
Programming
Touchpad
Cable (60-791)