GE 60-960-95 Home Security System User Manual


 
Concord Ultra 40
Reporting Menu
The REPORTING menu lets you set up which system events are reported to the central monitoring
station. The following describes how to program the reporting settings that appear under
GLOBAL.
Keychain TP Arm (partition 1: 0513, partition 2:
0523)
Touchpad Options-Partition 1-2 (Default = off)
When this setting is on, pressing the lock button on keychain
touchpads arms the system directly to AWAY with NO DELAY.
When this setting is off, each key-press increments the arming
level (i.e., from OFF to STAY, from STAY to AWAY).
¾
To change the Keychain Touchpad Arming setting:
1. With the display showing KEYCHAIN TP ARM OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Star Is No Delay (partition 1: 0514, partition 2: 0524)
Touchpad Options-Partition 1-2 (Default = off)
This setting determines whether the keychain touchpad star button
controls an output (off) or the No Delay feature (on).
¾
To change the keychain Star Is No Delay setting:
1. With the display showing STAR IS NO DELAY OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
24-Hour Tamper (06000)
Reporting-Global (Default = off)
When this setting is on, the panel sounds sirens and reports a
tamper alarm (even when the system is disarmed), when wireless
sensor tamper switches are activated.
¾
To turn 24-Hour Tamper off or on:
1. With the display showing 24 HOUR TAMPER OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Buffer Control (06001)
Reporting-Global (Default = off)
When this setting is on, only arming level changes are logged in
the buffer (memory) of the panel. When this setting is off, all sys-
tem events are logged in the buffer.
¾
To turn Buffer Control off or on:
1. With the display showing BUFFER CONTROL OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Back In Service (06002)
Reporting-Global (Default = on)
When this setting is on, the panel reports to the central station
when AC and backup battery power are restored (after an extended
power outage).
¾
To turn Back In Service reports off or on:
1. With the display showing BACK IN SERVICE OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
Bypass Reports (06003)
Reporting-Global (Default = off)
When this setting is on, the panel reports to the central station
whenever sensors or zones are bypassed.
¾
To turn Bypass Reports off or on:
1. With the display showing BYPASS REPORTS OFF/ON
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.