GE 60-960-95 Home Security System User Manual


 
Concord Ultra
49
Audio Verification Menu
The AUDIO VERIFICATION menu lets you set up the audio verification module (AVM) operation in
partition 1. If you want audio verification for partition 2, you must install a “stand-alone” audio
verification module and a 4-Relay Output Module (HOM) (60-770) output for that partition.
The following sections describe the audio verification settings that appear under
PARTITION 1.
Audio Verify (0900)
Audio Verification-Partition 1 (Default = off)
This setting determines
whether or not the system
can be accessed by phone for
alarm verification.
¾
To turn Audio Verification off or on:
1. With the display showing AUDIO VERIFICATION, press #. The display shows PARTITION 1.
2. Press # again and the display shows
AUDIO VERIFY OFF/ON (current setting).
3. Press 1 (off) or 2 (on). The display flashes the entered setting.
4. Press # and the display shows the new setting.
Audio Mode (0901)
Audio Verification-Partition 1 (Default = 1)
This setting determines how the audio verification module operates. Choose
one of the following:
(1) Instant—Allows the central station operator instant access for an
audio session by entering the AVM code or by pressing * (if an AVM
access code is not programmed) upon completion of panel alarm report
(also see
ACCESS TIMEOUT).
(2) Callback—Allows the central station operator to contact persons on
the premises after one ring and verify the alarm report. Operator must
press * or enter the AVM access code within 20 seconds after ring. The
panel does not report any alarms during the AVM session, except for fire
alarms.
(3) Callback Silent—Same as Callback, except premises phones do not
ring.
¾
To set Audio Mode:
1. With the display showing AUDIO VERIFY
OFF/ON
, press A or B until the display
shows
AUDIO MODE nn (current setting).
2. Enter the desired mode number (1–3). The
display flashes the entered setting.
3. Press # and the display shows the new set-
ting.
Fire Shutdown (0902)
Audio Verification-Partition 1 (Default = off)
This setting determines whether system sirens turn
off during a fire alarm audio session.
¾
To turn Fire Shutdown off or on:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until
the display shows
FIRE SHUTDOWN OFF/ON (current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting.
3. Press # and the display shows the new setting.
Silent Talkback (0903)
Audio Verification-Partition 1 (Default = off)
This setting determines whether the central station
operator can speak to persons on the premises (on)
or only listen (off) during a silent or duress alarm
audio session.
¾
To turn Silent Talkback off or on:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until
the display shows
SILENT TALKBACK OFF/ON (current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting.
3. Press # and the display shows the new setting.
Access Timeout (0904)
Audio Verification-Partition 1 (Default = 90 sec.)
If the Audio Mode is set to “Instant,” then this set-
ting determines how much time (30–300s, in 2-sec-
ond increments) the central station operator has to
enter the AVM access code after the panel is
accessed for an audio session.
¾
To change the Access Timeout:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until
the display shows ACCESS TIMEOUT nn SECS (current setting).
2. Enter the desired time. The display flashes the entered setting.
3. Press # and the display shows the new setting.