GE 60-960-95 Home Security System User Manual


 
L P
-
+
L N
1
2 3 4 5
6
1 0 1 1 1 2
1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1
2 4
V A C
2 4
V A C
+ 1 2
B U S
B U S
A
B U S
B
O U T P U T
2
G N D
M IC .
IN
Z O N E
1
Z O N E
2
Z O N E
4
G N D
Z O N E
3 G N D
G N D
Z O N E
5
Z O N E
6
Z O N E
7
2 2
2 3 2 4
Z O N E
8
2 - W IR E
S M O K E
IN
2 - W IR E
S M O K E
P O W E R
+
T E L C O
T IP
+
-
+
-
7
8
9
S P E A K E R
O U T P U T
1
T IP
( + )
R I N G
( -)
8
7
3
1 1
3
4
2 5
2 6 2 7
7 8
H O U S E
T IP
H O U S E
R I N G
T E L C O
R I N G
1
H IG H
2
G N D
3
L O W
4
1 0
4
9
6
1
2 3 4 5
4
5
6
3
4
5
6
3
4
5
6
3
1
+ 1 2 V
2
A
3
B
4
G N D
5
G N D
6
S P K 1
7
S P K 2
8
A U D 1
9
A U D 2
1 0
G N D
1 1
T IP 1
1 2
T IP 2
1 3
R IN G
2
1 4
R IN G
1
3 4 5
6
+ 1 2 V
A
B
G N D B U S
2 5
2 6 2 7
2 4
6 0 7 3 4 G 3 1 7 D .D S F
7
8
1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6
Z O N E C O M M O N
Z O N E 1
Z O N E 2
Z O N E 3
Z O N E 4
Z O N E 5
Z O N E C O M M O N
Z O N E C O M M O N
Z O N E 6
Z O N E 7
Z O N E C O M M O N
Z O N E 8
N O 1
N C 1
C O M 1
Z O N E 1
N O 2
N C 2
C O M 2
N O 3
N C 3
C O M 3
N O 4
N C 4
C O M 4
Z O N E C O M
1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7
1 8
Class II
24 VAC
30 or 50 VAC
Note 2:
SuperBus 2000 Fixed
Display Touchpad (60-820)
Or
2 x 16 LCD Alphanumeric
Touchpad (60-746-01)
Splice
Speaker
Note 3:
13-060
(15-Watt)
8 Ohm
Speaker
Note 4:
Note 5:
Normally
Closed
(N/C)
Contacts
In Series
Note 5:
Normally
Open
(N/O)
Contacts
In Parallel
2k Ohm EOL
Resistor (49-454)
2k Ohm
EOL Resistor
(49-454)
(Locate at
Last Sensor)
2k Ohm
EOL Resistor
(49-454)
(Locate at
Last Device)
2k Ohm
EOL Resistor
(49-454)
(Locate at
Last Detector)
To Panel
Terminal 4
Red
To
Premises
Phones
Black
Not
Used
Note 4 & 9:
Hardwire
Exterior
Siren 13-046
To Panel Terminals 7 & 8
or
Phone Interface/Voice Module
Terminals 6 & 7
Separate
Wire
Cables
Cable
Shield
Wire
Notes 3 & 8:
Audio Verification Module, 60-677
Note 6:
2-Wire
Hardwire
Smoke/Heat
Detector
(10 Maximum)
Note 5:
PIR Motion
Sensor 13-082
Note 3:
2
(15-Watt)
8 Ohm
Speaker
Note 3: Hardwire Interior Speaker 60-528
Not
Used
Phone
Connection
TELCO
Protector
Block
Black
Green
Red
White
or Yellow
White or
Yellow
Note 7:
RJ-31X
(CA-38A)
Phone Jack
DB-8
Cord
Brn
Gry
Grn
Red
Black
Grn
Red
Green
Red
Red
Green
Brown
Gray
Brn
Gry
Grn
Red
Note 7:
RJ-31X (CA-38A)
Phone Jack
Notes 3 & 7: SuperBus 2000 Phone Interface/Voice Module
Speaker Brn Gry RedGrn
(Partition 1 Voice
Module Only)
Panel
Terminals
Panel
Terminals
Panel
Terminals
Note 11:
SuperBus 2000 8Z
Input Module 60-774
Note 11:
SuperBus 2000 4-Relay
Output Module 60-774
Note 10:
SuperBus 2000 Energy
Saver Module 60-620-01
Thermostat
To Furnace
Optional SuperBus 2000 Module Connections
Note 1: CLASS II POWER
TRANSFORMER 60-779