GE 60-960-95 Home Security System User Manual


 
Concord Ultra 56
User Codes Menu
The USER CODES menu lets you program/change regular user access codes, partition master
codes, and the system master code. You can enter up to 230 separate user codes, allowing up to
230 different “users” access to the security system. You can also specify whether or not a specific
user is able to perform specific actions like, bypass sensors or test the system.
Time (020)
Time and Date (Default = 00:00)
This setting lets you adjust the panel clock to
the correct time. The panel uses a 24-hour
clock. For example, to set the time to 4:17
P.M.,
enter 1617.
¾
To set the Time:
1. With the display showing TIME AND DATE, press # and the display shows
TIME hh:mm (current time).
2. Enter the correct time (0000–2359). The display flashes the entered time.
3. Press # and the display shows the new time.
Date (021)
Time and Date (Default = 01/01/00)
This setting lets you adjust the
panel calendar to the correct
month, day, and year.
¾
To set the Date:
1. With the display showing TIME AND DATE, press #, then A or B until the display shows
DATE nn/nn/nn (current date).
2. Enter the correct month (01–12), day (01–31), and year (00–99). For example, enter
090100 for September 1, 2000. The display flashes the entered date.
3. Press # and the display shows the new date.
User NNN (030nnn0 where
nnn=user number 00-229)
User Codes-Reg. User Codes-User NNN (Default = none)
User codes perform basic arming
and disarming functions. The sys-
tem allows up to 230 user codes
(user numbers 00–229). User
numbers that show ****
indicate
no code is currently programmed
for that user number.
¾
To program Regular User Codes:
1. With the display showing USER CODES, press # and the display shows REGULAR USER
CODES.
2. Press #
and the display shows USER nnn (first available user number).
3. Press A or B to select the desired user number, then press #. The display shows
USER
nnn - nnnn.
4. With the desired user number displayed, enter a 4-digit user code. The display flashes
the entered code.
5. Press # and the display shows
USER nnn - nnnn (new code).
¾
To delete Regular User Codes:
1. With the display showing USER CODES, press # and the display shows REGULAR USER
CODES.
2. Press #
and the display shows USER nnn - nnnn (first available user number).
3. Press A or B to select the desired user number/user code you want to delete (if it is not
already displayed), then press #. The display shows
USER nnn - nnnn.
4. Enter the system or partition master code. The display flashes the entered code.
5. Press # and the display shows USER nnn -- **** (no code).