GE 60-960-95 Home Security System User Manual


 
Concord Ultra
65
For wireless sensors that don’t respond, use an RF Sniffer (60-401) test tool to verify that the sen-
sor is transmitting. Constant beeps from the RF Sniffer indicate a runaway (faulty) sensor.
Remove the sensor battery(s) and replace the sensor.
Testing Phone Communication
Perform a phone test to check the phone communication between the panel and the central moni-
toring station.
¾
To perform a phone test:
1. Contact the central monitoring station to inform them that you are testing the system.
2. Press 8 + system master CODE + 2. The display reads
PHONE TEST and the touchpad sounds
one beep. When the panel completes the test, the system returns to the previous arming level
automatically.
If the display continues to show
PHONE TEST for 1½ minutes or more, enter 1 + system master
CODE and refer to the “Troubleshooting” section.
Testing Central Station/Pager Communication
After performing sensor and phone tests, check that the system is reporting alarms successfully
to the central station or pager.
Be sure to contact the central monitoring station before activating outputs that trigger
from an alarm condition.
Note
The way information is dis-
played varies with pager ser-
vices and may not match the
example above. Account
numbers with alpha-charac-
ters also vary when dis-
played, depending on pager
service. Account numbers
are not displayed if
STREAMLINING is turned
on.
¾To test communication with the central station/pager:
1. Call the central station and tell the operator that you will be testing the system.
2. Arm the system.
3. Test each of the touchpad and wireless panic buttons and trip at least one sensor of each type
(fire, intrusion, etc.) to verify correct operation.
4. Check pager displays to verify reports are received. Pagers display an event code, digit sen-
sor number, and the last four digits of the account number. For example, a pager display of
999 002 7468 indicates the following:
999 = alarm condition,
002 = sensor/zone in alarm or user number,
7468 = last four digits of account number.
5. When you finish testing the system, call the central monitoring station to verify that the
alarms were received.
Table 10 describes pager system event codes.
Table 11 describes pager sensor/zone number and user number report codes.
Caution
!
Table 10: Pager System Event Codes
Code System Event
009 Zone Restoral
111 System Disarmed
115 Sensor Test Exit
118 Trouble condition cleared
119 Alarm Canceled
222 System Armed to STAY
333 System Armed to AWAY
555 Phone/Sensor Test
888 System Trouble Condition
999 System in Alarm
Table 11: Pager Sensor/Zone Code and Numbers
Code Sensor/Zone or User Number
000 System event not caused by a zone or user