Ring/Hang/Ring (partition 1: 0212, partition 2: 0222)
Phone Options-Partition 1-2 (Default = on)
This setting determines how the panel picks up (seizes) the phone line. Select
“on” if an answering machine shares the phone line with the panel. Select
“off” if there is no answering machine sharing the phone line with the panel.
Note
The Remote Access setting must be turned on for this feature to work.
When this feature is on, the person who is calling the panel must use the fol-
lowing procedure:
1. Listen for one or two full rings.
2. Hang up.
3. Call the premises again within the next 10–40 seconds. The system
answers after the first ring.
When this feature is off, the system answers after 12 full rings.
¾
To turn Ring/Hang/Ring access off or on:
1. With the display showing RING/HANG/
RING OFF/ON
(current setting), press 1
(off) or 2 (on). The display begins flash-
ing the entered selection.
2. Press # and the display shows the new
setting.
Line Fail Delay (partition 1: 0213)
Phone Options-Partition 1 only (Default = none)
This setting determines the amount of time the
partition 1 phone line voltage must be absent
before the panel indicates a phone failure trouble
condition. If a delay is not programmed (default),
the panel will not monitor the phone line voltage.
Note
Line Fail Delay is not available for partition 2 at this
time.
¾To set the Line Fail Delay time:
1. With partition 1 selected, press A or B until the display shows LINE
FAIL DELAY nn SECS
(current setting).
2. Enter the desired time value (10–240 seconds). The display flashes the
entered setting.
3. Press # and the display shows the new setting.
¾
To delete the Line Fail Delay time:
1. With partition 1 selected, press A or B until the display shows LINE
FAIL DELAY nn SECS
(current setting).
2. Press D to delete the current line fail delay time.
Toll Saver (partition 1: 0214, partition
2: 0224)
Phone Options-Partition 1-2 (Default = on)
This setting determines whether the panel
answers a phone call on the eighth ring (on) or
twelfth ring (off) when a trouble condition exists.
¾
To turn Toll Saver off or on:
1. With the desired partition selected, press A or B until the display
shows TOLL SAVER OFF/ON (current setting).
2.
Press 1 (off) or 2 (on). The display flashes the entered setting.
3. Press # and the display shows the new setting.
Phone Panic (partition 1: 0215, parti-
tion 2: 0225)
Phone Options-Partition 1-2 (Default = off)
This setting determines whether or not a police
panic alarm can be activated from a touch-tone
phone. When this feature is on, pressing # +
****** from a touch-tone phone on the premises
causes a panic alarm.
¾
To turn Phone Panic off or on:
1. With the desired partition selected, press A or B until the display
shows
PHONE PANIC OFF/ON (current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting.
3. Press # and the display shows the new setting.