GE 60-960-95 Home Security System User Manual


 
Concord Ultra
15
Note
Regardless of supervised or
unsupervised siren installa-
tion, you must follow the
order of installation as
described to avoid learning
the wrong (or undesired)
House Code and SWS
Supervision Code into siren
memory.
¾For unsupervised wireless siren installations:
1. Power up the panel (see “Powering Up the Panel”).
2. Enter program mode and set the partition House Code to the desired setting (see the
LIGHT
CONTROL
menu in the section “Programming the Panel”).
3. Exit program mode.
4. Install the siren backup battery.
5. Plug the siren into an electrical outlet.
6. Press the STATUS button on any working touchpad. The siren should beep once and the
siren LED should flash 5 times, indicating it has learned the partition House Code.
7. If the siren doesn’t beep or the LED doesn’t flash, reset the house code on the siren by press-
ing and holding its button for 20 seconds. The siren will beep three times when the memory
has been cleared. Repeat step 6.
¾
For supervised wireless siren installations:
1. Power up the panel (see “Powering Up the Panel”).
2. Install the siren backup battery.
3. Clear the siren memory by pressing and holding the siren button for 20 seconds. The siren
will beep three times when the memory has been cleared.
4. Enter program mode and set the partition House Code to the desired setting (see the
LIGHT
CONTROL
menu in the section “Programming the Panel”).
Note
When installing Supervised
Wireless Sirens for super-
vised operation, be sure to
program sensor text that
clearly identifies each siren.
For example, HALLWAY
SIREN or BASEMENT
SIREN. This can help both
you and your customer
locate a specific siren if a
problem occurs.
5. Proceed to the SIREN OPTIONS menu and set the SWS Supervision Code to the desired set-
ting.
6. Proceed to the
LEARN SENSORS menu and select the desired partition, sensor group 33, and
the desired sensor number.
7. When the touchpad display shows TRIP SENSOR nn, plug the siren into an electrical outlet.
The siren should beep once and the siren LED should flash 10 times, indicating the panel
learned the siren transmitter ID and that the siren learned both the partition House Code and
SWS Supervision Code.
8. Exit program mode.
Connecting an Interrogator 200 Audio Verification Module (60-677)
Connect the Interrogator 200 Audio Verification Module (AVM) to the panel terminals as shown
in Figure 13. Partition 1 use only.
Figure 13. Connecting an Interrogator 200 AVM to the Panel
If a speaker is already connected to panel terminals 7 and 8, the Interrogator 200
speaker must be hooked up in series with that speaker to provide a 16-ohm load. Hook-
ing up speakers in parallel to panel terminals 7 and 8 creates a 4-ohm load that can
cause permanent damage to the panel.
Caution
!
87
4
+ 1 2 V
3
G N D
1 1
M IC
Panel Terminals
Black
Yellow
Splice
Cable Shield
Speaker
Run Separate
Wire Cables
As Shown