The following sections describe the security settings that appear under PARTITION 1 and 2.
Dealer Code (0002)
Security-Global (Default = none)
The 4-digit dealer code is used to prevent unauthorized persons
from changing the programmed central station phone numbers.
When this feature is enabled, central station phone numbers
cannot be changed (unless you enter the program mode by
using the dealer code). All other system settings are still acces-
sible by entering the program mode with the installer code.
Note
The Dealer Code cannot be deleted by clearing panel memory.
¾To program a Dealer Code:
1. With the display showing DEALER CODE ****, enter the
desired 4-digit code. The display flashes the entered
code.
2. Press # and the display shows the new code.
¾
To delete a Dealer Code:
1. With the display showing DEALER CODE nnnn (current
code), press D. The display shows DEALER CODE ****.
Access Code Lock (0003)
Security-Global (Default = on)
This setting determines whether or not the panel will include Access
Codes when sending user information to the automation module.
When this option is on, it means the Access Codes are not sent.
¾
To turn Access Code Lock off or on:
1. With the display showing ACCESS CODE LOCK
ON/OFF
, press 1 (off) or 2 (on). The display
flashes the entered setting.
2. Press # and the display shows the new setting.
SIA False Alarm Reduction (0004)
Security-Global (Default = on)
Controls the following settings that are required by the SIA False Alarm Reduction
Standard:
Arming level changes made from wireless touchpads and keychain touchpads
are sounded (beeps) on exterior siren output (on) OR are not sounded on exte-
rior siren output (off).
Note
The siren output must be configured for “Exterior Siren” (016xx) and on the two onboard
outputs and SnapCard outputs only, for the arming level beeps to be annunciated.
The Arming Always Silent feature is disabled for users if this setting is on OR
can be controlled by users if the setting is off. Silent Arming on Demand is not
affected.
¾
To turn SIA False Alarm Reduction
off or on:
1. With the display showing SIA FALSE
ALARM (current setting), press 1
(off) or 2 (on). The display flashes
the entered setting.
2. Press
ƒ and the display shows the
new setting.
Account Number (partition 1: 0010, partition 2: 0020)
Security-Partition 1-2 (Default = 00000)
The account number is used as panel (or customer) identification for the
central monitoring station. The panel sends the account number every
time it reports to the central station. Account numbers must be 1 to 10
characters long.
Alpha characters A–F can be assigned to the account number by pressing
and holding buttons 1–6 respectively, until the character appears.
¾
To program an Account Number:
1. With the display showing ACCOUNT NUMBER
nnnnn
(current number), enter the desired
account number. The display flashes the
entered number.
2. Press # and the display shows the new number.
Quick Arm (partition 1: 0011, partition 2: 0021)
Security-Partition 1-2 (Default = off)
Quick Arm allows system arming without using an access code. When
Quick Arm is on, the system arming level can be increased from Level 1-
OFF to LEVEL 2-STAY, from Level 1-OFF to LEVEL 3-AWAY, or from
Level 2-STAY to LEVEL 3-AWAY, without entering an access code.
A valid access code is still required to decrease the arming level or disarm
the system.
¾
To turn Quick Arm off or on:
1. With the display showing QUICK ARM OFF/ON
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.