Brother S-7200C Sewing Machine User Manual


 
S-7200C
4.
FUNCTION SETTINGS (G50 OPERATION PANEL)
27
<Resolver signal test>
1
Select the test number
Test number Test name
[ ALL] All tests (Test 1-Test 7)
[TES1] Test 1 (Individual)
[TES2] Test 2 (Individual)
[TES3] Test 3 (Individual)
[TES4] Test 4 (Individual)
[TES5] Test 5 (Individual)
[TES6] Test 6 (Individual)
[TES7] Test 7 (Individual)
2
Start the test
A. For all tests ([ ALL])
B. For individual tests (example: [TES1])
NOTE:
Once testing has started, no items other than a resolver signal test can be checked. To check a different item,
carry out step 4 given below, and then change back to input check mode.
3
[If carrying out another resolver signal test]
1)
2)
Repeat steps 1 and 2 above.
4
[To return to the normal sewing machine starting condition]
1) Press the power OFF switch to turn off the power.
2) Check that the power indicator (green) on the operation panel has turned off, and then turn the power back on.
NOTE:
If you turn the power back on while the power indicator (green) is still illuminated, [E131] may be displayed.
A
ll tests from Test 1 to Test 7 are carried out.
If all tests are completed and the results are
all OK, [7 OK] will be displayed as the right
four characters in the main display.
If an NG result occurs during the test, [* NG]
will be displayed as the right four characters
in the main display. (* indicates the numbe
r
of the test which produced the NG result.)
The test specified by the number will be
carried out.
If the test is completed and the result is
OK, [* OK] will be displayed as the righ
t
four characters in the main display. If the
result is NG, [* NG] will be displayed.
2020B
2021B 2022B
2023B
Test number
Test number
Test result
(OK / NG)
Test number
Test result
(OK / NG)