Brother S-7200C Sewing Machine User Manual


 
S-7200C
4. FUNCTION SETTINGS (G50 OPERATION PANEL)
10
Sewing machine motor settings (100-)
No.
Setting
range
Initial
value
Setting
units
Setting details
100
1-99
(needles)
2
(needles)
1 Number of slow start stitches
101 OFF/1-3 OFF 1
Pedal response switching settings immediately after sewing has started
OFF: No switching
1: Slow start only when sewing starts after thread trimming
2: Slow start only when sewing starts after sewing has been paused
3: Slow start always when sewing starts
102 1-5 1 1
Pedal response immediately after sewing has started
* The larger the value, the slower the speed when sewing starts.
* If No. 101 is set to “OFF”, this setting is disabled.
Operation panel settings (300-)
No.
Setting
range
Initial
value
Setting
units
Setting details
300 1-3 1 1
Lower thread counter display operations
1: Lower thread counter (Counting units are set by No. 301.)
2: Thread trimming counter (incremented by 1 each time of a thread trimming
operation occurs)
* The counter is incremented even if thread trimming is set to disabled.
3: Needle replacement counter (Counting units are set by No. 303.)
301
0-100
(needles)
10
(needles)
1
Lower thread counter counting units
0: No counting operation
1-100: Display counts down by the set number of stitches
302 0-2 1 1
Operation for counter warning (when < ! > warning icon is displayed)
0: Starting using the treadle is always enabled
1: After thread trimming stops, starting using the treadle is disabled
(enabled until depressed backward)
2: Operation using treadle fully disabled after treadle is returned to neutral
position and sewing stops
303
0-1000
(needles)
100
(needles)
10
Needle replacement counter counting units
0: No counting operation
10-1000: Display counts down by the set number of stitches