4. FUNCTION SETTINGS (G50 OPERATION PANEL)
19
Sewing program settings (450-)
No.
Setting
range
Initial
value
Setting
units
Setting details
450 ON/OFF OFF -
Correction sewing using actuator switch after thread trimming
* This is only enabled when No. 500 is set to “1”.
ON: Enabled
OFF: Disabled (switch operation disabled)
451 ON/OFF (*1) -
Speed for moving to end backtack
(Set to “ON” if you want cycle time to be shorter.)
OFF: Decelerates to low speed, then end backtacking starts
ON: Decelerates to end backtacking speed, then end backtacking starts
* If No. 452 has been set to “ON”, the operation when No. 451 is set to “ON”
will be disabled.
452 ON/OFF OFF -
Seam matching function during automatic backtacking
(Set to “ON” if you want to match seams accurately during automatic
backtacking.)
ON: Momentarily stops when material feed direction is changed
OFF: No stopping when material feed direction is changed
* The stopping position for No. 453 can be changed by changing the time
before restarting using No. 454.
453
0-350
(degrees)
180
(degrees)
10
Momentary stopping position when material feed direction is changed
(The stopping position is the angle from when the needle up signal turns ON.)
* This is only enabled when No. 452 is set to “ON”.
454
10-500
(ms)
100
(ms)
10
(ms)
Momentary stopping time when material feed direction is changed
(The quick reverse mechanism switches at the stopping position, and then
after the stopping time has elapsed, sewing automatically restarts.)
* This is only enabled when No. 452 is set to “ON”.
455
OFF/
1-2
(*2) 1
Synchronization function when quick reverse mechanism has been operated
using the actuator switch
OFF: Disabled (Quick reverse mechanism is synchronized with switch)
1: Quick reverse mechanism synchronization without motor deceleration
2: Quick reverse mechanism synchronization when motor decelerates
automatically to the speed set by No. 456
456
300-4000
(sti/min)
4000
(sti/min)
100
Automatic deceleration speed when quick reverse mechanism has been
operated using the actuator switch
* This is only enabled when No. 455 is set to “1” or “2”.
457
0-355
(degrees)
0
(degrees)
1
Quick reverse mechanism operation angle at low speed (less than 1000
sti/min)
* This is only enabled when No. 455 is set to “1” or “2”.
458
0-355
(degrees)
150
(degrees)
1
Quick reverse mechanism operation angle at high speed (1000 sti/min or
more)
* This is only enabled when No. 455 is set to “1” or “2”.
471 ON/OFF
OFF
(*3)
- Spare
(*1) The initial value varies depending on the destination. For Japan, the initial value is “ON”, and for all other destinations, it is “OFF”.
(*2) The initial value varies depending on the destination. For Japan, the initial value is “OFF”, and for all other destinations, it is “2”.
(*3) This is not initialized during initialization mode.