Brother S-7200C Sewing Machine User Manual


 
S-7200C
4. FUNCTION SETTINGS (G50 OPERATION PANEL)
22
-. Data initialization function
NOTE:
When DIP switch 1 is set to ON, set it to OFF and then carry out the following operations.
1
Change to initialization mode
(While pressing the RESET key, press the power ON switch.)
2
Select the item to be initialized
Item No. Main display Details to be initialized
1 [INIT ALL]
Clears all settings
(Items 2, 3 and 4 will be initialized.)
2 [INIT MEM] Memory switches
3 [INIT SPD]
Speed setting (MAX, Speed bar)
Settings for memory switch
Nos. 180-189
4 [INIT SEW]
Sewing programs
(operation panel display)
3
(Press for 2 seconds or more)
4
“init ALL” will appear in orange
in the main display (1).
Once initialization is complete, the main display (1) will return to
green.
NOTE:
If the initialization items are changed after initialization, the
color will return to orange
.
Initialization mode will be exited and normal sewing machine
operation will then be possible.
4193M
2094B
4195M
4192M