HP (Hewlett-Packard) 20-Feb Air Cleaner User Manual


 
Appendix Library Error Codes 217
Appendix C
111 6fH Slave controller card
missing or faulty.
Ensure the slave controller card is installed and fully
seated.
112 70H Slave board
command timeout.
Retry command.
113 71H Slave controller card
failed self test.
Power cycle the library.
114 72H Slave controller card
failed initialization.
Power cycle the library.
118 76H Slave controller is on
level 1.
Remove slave controller card from the bottom level
of the library.
120 78H Library controller
unable to
communicate with
Fibre Channel card.
Ensure Fibre Channel card is installed and fully
seated.
121 79H Failed to detect all of
the Fibre Channel
cards.
Power cycle the library.
122 7AH Fibre Channel board
command timeout.
Power cycle the library.
123 7BH A Fibre Channel card
has failed.
Power cycle library and retry. Replace card if
unsuccessful (Removing and Replacing Cards on
page 160).
126 7EH More than one Fibre
Channel card is on a
library level.
Remove duplicate Fibre Channel card.
130 82H Library controller
unable to
communicate with
remote management
card.
Power cycle the library.
Table 46
Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description Recovery Method