HP (Hewlett-Packard) 20-Feb Air Cleaner User Manual


 
156 Diagnostic Support Tools Chapter 4
Running Library Diagnostic Tests
Use the following procedure to run internal tests of library functions. Table 28
on page 156 describes these tests.
1. From Administration, select [More] to display additional administrative
options. Select
[Run Test].
2. From Run Test, use the [-] or [+] key to view available tests.
3. Select [OK] to select the test.
4. Select the number of times this test will run.
5. Select [Run] to start the test cycle. The test results will display at the
conclusion of the test cycle.
Note Select [Stop] to abort a test. The current test cycle completes
before the test stops. Stopping the test may take a few minutes.
Main Menu -> Administration -> Run Test
Table 28 Front Panel Diagnostic Tests
Test Description
Check Inventory Physically scans the entire library to determine
which slots and drives contain tapes and reads all
bar code labels.
Recalibrate Library Performs the power-up self-tests. Each test runs one
time per test loop. This test recalibrates the
mechanics and clears hard errors, but not the hard
error log.
Test Lateral Motion Moves the transport assembly to a random slot. No
tape is required.
Test Magazine
Moves
Moves a tape from a random slot to an empty,
random slot, and then returns it to the original
location.