HP (Hewlett-Packard) 20-Feb Air Cleaner User Manual


 
Appendix Library Error Codes 211
Appendix C
11 0BH Failed plunge motor
test.
Note the error code qualifier to help determine
appropriate testing.
12 0CH Transport failed to
find the translate
home position.
Make sure that all tape cartridges are fully
seated in their slots.
13 0DH Transport failed to
find the vertical home
position.
Check for a possible obstruction in the
transport pathway and remove it.
Verify that the vertical path is physically clear.
Make sure that all tape cartridges are fully
seated in their slots. (When manually loaded,
cartridges may not have been fully inserted into
slots.)
14 0EH Transport failed to
find the plunge home
position.
The plunge motor can be moved. Therefore, the
motor and umbilical cable are probably not
indicated.
Replace the transport assembly.
15 0FH Has wrong library
family firmware or the
controller is on the
wrong level.
Download new firmware (see Upgrading Firmware
on page 176).
18 12H Failed because
magazine door) is
open.
Close magazine doors.
19 13H Vertical motor cable is
missing or faulty.
Check that the vertical cable connections are
secure.
20 14H Transport umbilical
cable is missing or
faulty.
Check the transport cable connections or the cable
that goes from the transport to the library.
Table 46
Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description Recovery Method