122 Understanding Error States Chapter 4
Drive online
pending
Drive(s) are present and powered
up, but have outdated firmware.
Update drive firmware. (See
Upgrading Firmware on
page 176.)
Drive firmware
mismatch
Drives are present and powered up,
but have different revisions of
firmware.
Update drive firmware. (See
Upgrading Firmware on
page 176.)
Drive needs
cleaning
One or more drives need cleaning.
Clean the drive(s). (See Cleaning a
Drive on page 87.)
Drive critical error A critical error has occurred on a
drive.
Check the Drive Event Log from the
front panel or RMC Web-Based
Library Administrator pages for
possible causes.
Contact your service
representative.
Drive not on Fibre
Channel
Drive(s) are detected by library
controller, but are not detected by
any of the Fibre Channel
controllers.
Verify that Fibre Channel is your
intended configuration.
Verify that cabling is set up
correctly.
Verify that there are no broken or
bent pins on the SCSI cables (for
standard performance Fibre
Channel controller only).
Tighten all SCSI cables and power
cycle the library.
If problem persists, replace the
SCSI cables.
Contact your service
representative.
Table 18
Partial Availability Conditions
Library Status Cause Solution