HP (Hewlett-Packard) 20-Feb Air Cleaner User Manual


 
210 Library Error Codes Appendix
Table 46 Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description Recovery Method
0 00H Error code not set. Power cycle the library.
Observe the LEDs on the back of the library
controller card. See Interpreting Library LEDs
on page 130 to understand what the LEDs may
indicate.
1-8 01H -
08H
Failed library
controller self test.
01h through 08h are controller tests. These errors
are possible only on power-up.
Power cycle the library.
Observe the LEDs on the back of the library
controller card. See Interpreting Library LEDs
on page 130 to understand what the LEDs may
indicate.
If failure persists, the library controller card
may be faulty.
9 09H Failed translate motor
test.
Cannot translate the transport.
Check for a possible obstruction in the
transport pathway and remove it.
The umbilical cable may be faulty.
If the transport moves a little, but cannot fully
rotate around the assembly, a faulty motor is
indicated.
10 0AH Failed vertical motor
test.
Occurs when trying to sense if the transport
assembly moves vertically. If the assembly does not
move:
Ensure that the motor leads are connected to
the vertical motor and the vertical lift board.
Check the umbilical cable under the translate
frame.