212 Library Error Codes Appendix
21 15H A chassis fan is
disconnected or
faulty.
Check that the chassis fan cable connection is
secure.
22 16H Chassis interconnect
cables are
disconnected or
faulty.
Check that the chassis interconnect cables are
secure.
23 17H Front panel cable is
disconnected or
faulty.
Check that the front panel cable connections are
secure.
24 18H Transport bar code
reader failed self test.
Power cycle the library.
25 19H Library levels
measured does not
match the number of
levels detected.
Check for obstructions in the vertical path.
Check that the chassis interconnect cable
connection is secure.
26 1AH Upper level fan cable
failed.
See Troubleshooting Common Problems on
page 140 for troubleshooting procedures.
27 1BH Transport controller
unable to
communicate with
transport.
Replace the transport assembly.
28 1CH Transport controller
needs new firmware.
Update the library’s firmware (see Upgrading
Firmware on page 176).
29 1DH Failed transport
firmware download.
Update the transport’s firmware (see Upgrading
Firmware on page 176).
50 32H Test not run, an
invalid test number
was specified.
If incorrect test number was designated when
initiating a test over the SCSI interface, select
desired number and then re-initiate the test.
Table 46
Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description Recovery Method