5.2.5 Preparing (creating) the program configuration
5 CREATING TWO OR MORE PROGRAM BLOCKS
GX Works2
3. Select "POU" "Program" on the Project view,
right-click "Program", and then select the menu
item "Add New Data".
The "New Data" screen appears.
When creating a new project, GX Works2 automatically creates "POU_01 [PRG]" under "POU_Pool".
Because the language (Structured Ladder/FBD) used in this chapter is same as the language adopted in
"POU_01 [PRG]", you can use "POU_01 [PRG]" by changing its data name instead of deleting it.
4. Set the "Data Type", "Language" and "Data
Name".
Click the button to create a program block
and close the window.
Repeat the steps 3 and 4, and create three program
blocks for the tea pouring operation, water refilling
operation and warning indicating operation.
Settings
Data Type : Select "Program Block".
Data Name : Input the following names:
1) pouring
2) refilling
3) indicating
Language : Select "Structured Ladder/FBD".