3 - 8
3.2.5 Setting labels
3 CREATING PROGRAM IN STRUCTURED LADDER/FBD LANGUAGE
GX Works2
3.2.5 Setting labels
Set Global Labels.
1. Double-click "Global Label" "Global1" on the
Project view to display the Global Label Setting
screen.
2. Select the "Class" from the list box on the
Global Label Setting screen.
Settings
• Class: VAR_GLOBAL
3. Directly input the "Label Name" on the Global
Label Setting screen.
Settings
• Label Name: VAR1
Restrictions
● Characters available for the label name
You can enter up to 32 characters as the label name.
However, note that the following label name will cause a compile error.
• Label name which contains space
• Label name whose first character is a number
• Label name equivalent to a device name
For other characters unavailable for the label name, refer to the following manual.
GX Works2 Version 1 Operating Manual (Common)
(To the next page)