Mitsubishi Electronics SW1DNC-GXW2-E Water System User Manual


 
5.4.1 Monitoring a program
5 - 17
1
OVERVIEW
2
CREATED PROGRAM
AND SYSTEM
CONFIGURATION
3
CREATING PROGRAM IN
STRUCTURED LADDER/
FBD LANGUAGE
4
CREATING
PROGRAM IN ST
LANGUAGE
5
CREATING TWO OR
MORE PROGRAM
BLOCKS
5.4 Monitoring Operations
5. Turn ON inputs X0, X1 and X2 in the programmable controller, and check the following
operations.
You can turn ON inputs X0, X1 and X2 using the test operation above.
When X1 turns ON while X0 is ON, the programmable controller turns ON Y10. When X1 turns
ON while X0 is OFF, the programmable controller does not turn ON Y10.
When X3 turns ON, the programmable controller turns ON Y11.
When X4 turns ON while X3 is ON, the programmable controller turns OFF Y11.
When Y11 turns ON/OFF 5 times, the programmable controller turns ON Y12.
When X2 turns ON, the programmable controller turns OFF Y12.
X1 (Tea_pouring_button) turns ON
while X0 (Cup_detection) is ON.
The programmable controller turns ON Y10
(Tea_pouring_output).
X3 (Lower_LS_of_water
_tank) turns ON.
The programmable controller turns ON Y11
(Water_refill_output).
X4 (Upper_LS_of_water
_tank) turns ON.
The programmable controller turns OFF
Y11 (Water_refill_output).
Y11 (Water_refill_output)
turns ON/OFF 5 times.
The programmable controller
turns ON Y12
(Replacement_indicator_lamp).
X2 (Tea_leaf_check_button)
turns ON.
The programmable controller turns OFF Y12
(Replacement_indicator_lamp).
(To the next page)