HP (Hewlett-Packard) HP 8360 Vacuum Cleaner User Manual


 
General
Environmental
Warm-Up Time
Power Requirements
Weight
&
Dimensions
Adapters Supplied
Operating Temperature Range: 0 to
55°C
EMC: Within limits of VDE 0871/6.78 Level B, FTZ 1046/1984, and
Mil-Std-461B Part 7 RE02
Operation: Requires 30 minute warm-up from cold start at 0 to
55°C. Internal temperature equilibrium reached over 2 hour warm-up
at stable ambient temperature.
Frequency Reference: Reference time base is kept at operating
temperature with the instrument connected to AC power.
Instruments disconnected from AC power for more than 24 hours
require 30 days to achieve time base aging specification. Instruments
disconnected from AC power for less than 24 hours require 24 hours
to achieve time base aging specification.
48 to 66 Hz; 115 volts
(+lO/-25%)
or 230 volts
(+lO/-15%);
400
VA maximum (30 VA in standby)
Net Weight: 27 kg (60 lb)
Shipping Weight: 36 kg (80 lb)
Dimensions: 178 H x 425 W x 648 mm D (7.0 x 16.75 x 25.5 inches)
HP
8362QA,
83622A, 83623A, 83624A,
0363QA
Type-N (female)
-
3.5 mm (female)
Part number 1250-1745
3.5 mm (female)
-
3.5 mm (female)
Part number 5061-5311
HP 83640A,
83650A
2.4 mm (female)
-
2.92 (female)
Part number 1250-2187
2.4 mm (female)
-
2.4 mm (female)
Part number 1250-2188
2~14
Specifications