ANALYZER STATUS REGISTER
AM Type
100%/V
Function Group
Menu Map
Description
Programming Codes
See Also
MOD (MODULATION)
4
This softkey (Option 002 only) scales the amplitude modulation
function linearly. The amplitude of the RF output changes linearly
as a function of AM input changes (or at a rate set by
softkey for
internal AM).
S
ee“Specifications” for the AM characteristics, input
range, and damage level. An asterisk next to the key label indicates
that this feature is active.
SCPI:
AM:TYPE
LINear
.
Analyzer:
AM1
function on, AM0 function off
m),
CONNECTORS,
(MOD_)
“Optimizing Synthesizer Performance” in Chapter 1.
ANALYZER STATUS
REGISTER
Function Group
NONE
Menu Map
NONE
Description
The following is the status register structure of the synthesizer when
the analyzer programming language is selected. This status structure
is the structurally and syntactically the same as on the HP
8340/41.
OS(2B) Output Status bytes, is used to read the two 8-bit status
bytes from the synthesizer. The first status byte concerns
the cause of an SRQ
(S
ervice
Request), while the second
status byte concerns failures and faults, as follows:
HP 8360
User’s Handbook
Operating and Programming Reference
A-19