Baldor MN1928 Home Security System User Manual


 
Specifications 8-3MN1928
8.1.6 Digital outputs - general purpose (non-isolated)
This specification is for the NextMove ES card when used separately or in conjunction with the
optional non-isolating backplane BPL010-501:
Description Unit Value
Load supply v oltage
(maximum)
V 50
Output current
Max. sink per output, one output on
Max. sink per output, all outputs on
mA DOUT0-7 DOUT8-11
500 400
150 50
Update interval I mmediate
8.1.7 Digital outputs - general purpose (opto-isolated)
This specification is for the optional opto-isolating backplanes BPL010-502 or BPL010-503,
when used in conjunction with the NextMove ES card.
Description Unit Value
USR V+ supply volta ge
Maximum
Minimum
VDC
30V
12V
Output current (BPL010-502)
Max. source per output, one output on
Max. source per output, all outputs on
mA DOUT0-7 DOUT8-11
350 400
75 50
Output current (BPL010-503)
Max. sink per output, one output on
Max. sink per output, all outputs on
mA DOUT0-7 DOUT8-11
500 400
150 50
Update interval I mmediate
8.1.8 Digital output - error output (non-isolated)
This specification is for the NextMove ES card when used separately or in conjunction with the
optional non-isolating backplane BPL010-501:
Description Unit Value
Output voltage V 5
Output current
(maximum)
mA 100
Update interval I mmediate