Baldor MN1928 Home Security System User Manual


 
5-14 Input / Output MN1928
5.3.2 Analog outputs (demands)
Location X7
Mating connector: Weidmüller Omnimate BL 3.5/12
Pin Name Description NextMove ES
96-pin
connector
12 Shield Shield connection a32
11 AGND Analog ground a30
10 DEMAND3 Analog output AOUT3 b22
9 Shield Shield connection a32
8 AGND Analog ground a30
7 DEMAND2 Analog output AOUT2 b17
6 Shield Shield connection a32
5 AGND Analog ground a30
4 DEMAND1 D emand 1 output (AOUT1) b27
3 Shield Shield connection a32
2 AGND Analog ground a30
1 DEMAND0 D emand 0 output (AOUT0) c27
The outputs on the backplane are connected directly to the NextMove ES and do not pass
through any circuitry on the opto-isolator card. See section 4.3.2 for electrical specifications of
the analog outputs.
Backplane
1
2
96
pin
connector
’X7’
NextMove ES
Demand
±100%
120k
30k
-
+
100pF
TL084
47R
DEMAND0
AGND
Figure 19 - Analog output, DEMAND0 shown
1
12