Baldor MN1928 Home Security System User Manual


 
8-2 Specifications MN1928
8.1.4 Digital inputs (non-isolated)
This specification is for the NextMove ES card when used separately or in conjunction with the
optional non-isolating backplane BPL010-501:
Description Unit Value
Type +5V inputs, non-isolated
Input voltage
Maximum
Minimum
High
Low
VDC
5.5
0
>3.5V
<1.5V
Input current (approximate, per input) mA 0.5
Sampling interval ms 1
8.1.5 Digital inputs (opto-isolated)
This specification is for the optional opto-isolating backplanes BPL010-502 or BPL010-503,
when used in conjunction with the NextMove ES card.
Description Unit Value
Type Opto-isolated
USR V+ supply volta ge
Maximum
Minimum
VDC
30
12
Input voltage
BPL010-502 ‘active high’ inputs
BPL010-503 ‘active low’ inputs
VDC
Active: >12V
Inactive: <2V
Active: 0V
Inactive: Unconnected
Input current
(maximum per input, USR V+ = 24V)
mA 10