Heat & Glo LifeStyle RED60 2159-900 Indoor Fireplace User Manual


 
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 69
Non-CombustibleFinishMaterials
0to1-1/4inchthickness-OverlapFitMethod
The mesh front is designed to overlap nish materials 0
inches to 1-1/4 inch thick. See Figure 13.7.
NOTICE: This 1-1/4 inch maximum not only includes the
decorative nish materials (marble, tile, slate, etc) but also
the thin set, lath and adhesive used to attach the decorative
nish material.
The non-combustible nish material can be installed up
to the 17-1/8 inch (height) by 62-3/4 inch (width) replace
opening.
Figure13.7OverlapFitMethod
= NO SCREWS IN THIS AREA
= 2 IN. MAX. SCREW LENGTH
SIDE FINISH NON-COMBUSTIBLE BOARD (2)
68 IN. WIDTH
FACTORY INSTALLED NON-COMBUSTIBLE BOARD
30-7/8 IN. HEIGHT
FACTORY INSTALLED
NON-COMBUSTIBLE
BOARD
Figure13.6Non-CombustibleFinishMaterialDiagramfor
0-1-1/4InchThickOverlapFitMethod
= AIR SPACE
7 IN.
1 IN.
0-1-1/4 IN.
0-1-1/4 IN. THICK DRYWALL
OR EQUIVALENT
STANDARD
DECORATIVE FRONT
SHOWN
FACTORY-INSTALLED
NON-COMBUSTIBLE
BOARD
13-3/4 IN.
NON-COMBUSTIBLE BOARD
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specied in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
WARNING! Risk of Fire! DO NOT install drywall or
other combustible materials directly onto the factory-
installed non-combustible board. Overlapping materials
could ignite.
Decorative facing material thickness is measured from
the face of the factory-installed non-combustible board.
See Figure 13.5.
The mesh front can be installed such that it overlaps non-
combustible materials up to 1-1/4 in. thick. See Figure
13.6.Refer to Section 1.E and 1.F of this manual for de-
nition and qualications and denition of non-combustible
and combustible materials.
Specic requirements for each method if installation are
described below and on the following pages of this section.
The mesh decorative front is approved for inside t ap-
plications. Non-combustible nishing materials up to 4
inches thick can be installed around the Mesh front (left,
right, top, and bottom). See Figure 13.8.
Figure13.8InsideFitMethod
Non-CombustibleFinishMaterials
0Inchesto4InchesThick-InsideFitMethod
1/2 IN. THICK
WALL SHEATHING
0-4 IN.
20-1/2 IN.
0- 4 IN.
1/2 IN.
1/2 IN.
19-1/2 IN.
DRYWALL OR
EQUIVALENT (1/2 IN.)