Heat & Glo LifeStyle RED60 2159-900 Indoor Fireplace User Manual


 
Heat & Glo • RED60 • 2159-900 Rev. R • 9/1230
Figure7.22
TopVent-HorizontalTermination
Ventingwith1elbow
H
1
V
1
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling restops.
ALWAYS maintain specied clearances around venting and restop systems.
Install wall shield and ceiling restops as specied.
Failure to keep insulation or other material away from vent pipe may cause re.
WARNING
Note: Use DVP Series
components only.
V
1
Minimum V
1
+ H
1
Maximum
2 ft. 610 mm 60 ft. 18.3 m
3 ft. 914 mm 70 ft. 21.3 m
4 ft. 1.2 m 80 ft. 24.4 m
V
1
+ H
1
= 80 ft. (24.4 m) Maximum
Note: Must have 24 inches minimum
vertical vent prior to attaching any
elbow to the appliance.
Note: PVI-DVP can be located in any
position except V
1.
I. VentDiagrams
WARNING! Risk of re and burns!
DO NOT install PVI-DVP with the
access panel facing upward. Over-
heating may occur.