Heat & Glo LifeStyle RED60 2159-900 Indoor Fireplace User Manual


 
Heat & Glo • RED60 • 2159-900 Rev. R • 9/1232
H
1
H
2
V
2
V
1
Note: Use DVP Series
components only.
1. TopVent-HorizontalTermination - (continued)
Figure7.24
V
1
Minimum V
1
+ V
2
+ H
1
+ H
2
Maximum
2 ft. 610 mm 40 ft. 12.2 m
3 ft. 914 mm 50 ft. 15.2 m
4 ft. 1.2 m 70 ft. 21.3 m
V
1
+ V
2
+ H
1
+ H
2
= 70 ft. (21.3 m) Maximum
Note: PVI-DVP can be located in any
position except V
1
.
TopVent-HorizontalTermination
Ventingwith3elbows
Note: Must have 24 inches minimum
vertical vent prior to attaching any
elbow to the appliance.
TopVent-HorizontalTermination
Ventingwithmorethan3elbows
Note: Use DVP Series
components only.
Note: PVI-DVP can be located in any
position except V
1
.
4Elbows
V
1
Minimum Total V + Total H Maximum
2 ft. 610 mm 30 ft. 9.1 m
3 ft. 914 mm 40 ft. 12.2 m
4 ft. 1.2 m 60 ft. 18.3 m
TOTAL V + TOTAL H = 60 ft. (18.3 m) Maximum
5Elbows
V
1
Minimum Total V + Total H Maximum
2 ft. 610 mm 30 ft. 9.1 m
3 ft. 914 mm 40 ft. 12.2 m
4 ft. 1.2 m 50 ft. 15.2 m
Total V + Total H = 50 ft. (15.2 m) Maximum
6Elbows
V
1
Minimum Total V + Total H Maximum
2 ft. 610 mm 10 ft. 3.0 m
3 ft. 914 mm 20 ft. 6.0 m
4 ft. 1.2 m 40 ft. 12.2 m
Total V + Total H = 40 ft. (12.2 m) Maximum
Note: Must have 24 inches minimum
vertical vent prior to attaching any
elbow to the appliance.
WARNING! Risk of re and burns!
DO NOT install PVI-DVP with the
access panel facing upward. Over-
heating may occur.
WARNING! Risk of re and burns!
DO NOT install PVI-DVP with the
access panel facing upward. Over-
heating may occur.