Heat & Glo LifeStyle RED60 2159-900 Indoor Fireplace User Manual


 
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 47
NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run
V1
H2
H1
V2
MAXIMUM
VERTICAL
DROP
DIRECTVENTWITH2FT.MINIMUMVERTICAL(V
1
)OFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN(FT.)
TotalV+TotalH
MAX.VERT.DROP(FT.)
V
2
3 24ft. 7ft.
4 17ft. 7ft.
DIRECTVENTWITH3FT.MINIMUMVERTICAL(V
1
)OFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN(FT.)
TotalV+TotalH
MAX.VERT.DROP(FT.)
V
2
3 29ft. 7ft.
4 22ft. 7ft.
DIRECTVENTWITH4FT.MINIMUMVERTICAL(V
1
)OFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN(FT.)
TotalV+TotalH
MAX.VERT.DROP(FT.)
V
2
3 34ft. 7ft.
4 26ft. 7ft.
Figure7.49
Note: 1 ft. of vertical drop decreases
horizontal length by 2 ft.