Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 65
Figure12.10RemoveBlower
8. Remove mounting plate from blower by removing the
four screws that hold the blower to the plate. Save the
gasket for use with the new blower. See Figure 12.11
and Figure 12.12.
Figure12.11RemoveMountingPlate
Figure12.12RemoveMountingPlate
9. Attach new blower to mounting plate by fastening the
four screws in the appropriate locations. The side of the
blower with the label on it must face toward the inside
of the appliance. This is the direction of the air ow.
See Figure 12.13.
Figure12.13RemovedMountingPlate
10. To install new blower back into appliance, reverse the
removal procedure. Install blower assembly with the
tab toward the rear of the appliance. See Figure 12.14.
This tab must insert into slot on blower housing inside
the appliance as shown in Figure 12.15.
Figure12.14BlowerTabTowardRear
Figure12.15BlowerTabInsertedintoSlotonBlowerHousing
BLOWERTABON
MOUNTINGPLATE
SLOTON
BLOWERHOUSING