Heat & Glo LifeStyle RED60 2159-900 Indoor Fireplace User Manual


 
Heat & Glo • RED60 • 2159-900 Rev. R • 9/12 37
NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run
V1
H1
H2
H3
V2
MAXIMUM
VERTICAL
DROP
DIRECTVENTWITH2FT.MINIMUMVERTICALOFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN
TotalV+TotalH(FT.)
MAX.VERT.DROP
V
2
(FT.)
3 34ft. 7ft.
4 22ft. 7ft.
5 22ft. 7ft.
1ft.verticaldropdecreaseshorizontallengthby2ft.
Note: 1 ft. of vertical drop decreases
horizontal length by 2 ft.
Figure7.29PowerVentPositionedAfterVerticalDrop
DIRECTVENTWITH3FT.MINIMUMVERTICALOFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN
TotalV+TotalH(FT.)
MAX.VERT.DROP
V
2
(FT.)
3 40ft. 7ft.
4 30ft. 7ft.
5 30ft. 7ft.
1ft.verticaldropdecreaseshorizontallengthby2ft.
DIRECTVENTWITH4FT.MINIMUMVERTICALOFFTOPOFAPPLIANCE
MAX.ELBOWS
(45°&90°)
MAX.TOTALVENTRUN
TotalV+TotalH(FT.)
MAX.VERT.DROP
V
2
(FT.)
3 56ft. 7ft.
4 50ft. 7ft.
5 40ft. 7ft.
6 30ft. 7ft.
1ft.verticaldropdecreaseshorizontallengthby2ft.